Universal motor Power: 0.5 HP Voltage: 120 volt Frequency: 60 Hz Enclosure: Explosion proof
Class I Groups C + D
Class II Groups F + G
Variable speed control, 16' cord
Technical Data - ME I 6 & Tube Combinations
Pump tubes
MMS-PP
MSL-PP
41-R SS/HC
MMS-PP
MSL-PP
41-L SS/HC
MMS-PVDF
MSL-PVDF
41-R HC
MMS-PVDF
MSL-PVDF
41-L HC
MMS-ALU
MSL-ALU
41-R
MMS-ALU
MSL-ALU
41-L
MMS-SS
MSL-SS
41-R
MMS-SSMSL-SS
41-L
Mechanical Seal (MS) Sealless (SL)
MS / SL
MS / SL
MS / SL
MS / SL
MS / SL
MS / SL
MS / SL
MS / SL
Max. Temperature
122 °F
122 °F
212 °F
212 °F
212 °F
212 °F
212 °F
212 °F
Type of impeller
Rotor
Impeller
Rotor
Impeller
Rotor
Impeller
Rotor
Impeller
Zone 0
No
No
No
No
No
No
Yes
Yes
Quantity*
Up to GPM
X
X
X
X
X
X
48.5
27
Delivery head*
Up to FT
X
X
X
X
X
X
33
54
Viscosity**
Up to cps
X
X
X
X
X
X
300/500
600/750
Spec. gravity***
Up to
X
X
X
X
X
X
1.3
1.7
Weight lbs.
Motor + pump tube
X
X
X
X
X
X
20.7
20.7
*Determined with water at 68 °F. ** Determined with oil. Continuous/ intermittent duty (10 min.) ***Determined with 10 feet 3/4" hose and open discharge. ***Higher densities possible for shorter operating periods. X Not a suggested combination
Pump tubes
SL-HC
42-R
RE 88 PP
40-L
RE 88 SS
41-L
MP MS-PP
MP SL-PP
50/41-L
MP MS-SS
41-R
B70V-SR
25.1 PTFE
B70V-SR 25.1 PTFE
Mechanical Seal (MS) Sealless (SL)
SL
MS
MS
MS
MS
Packed Gland
MS
Max. Temperature
248 °F
122 °F
212 °F
122 °F
212 °F
284 °F
284 °F
Type of impeller
Rotor
Impeller
Impeller
Impeller
Rotor
--
--
Zone 0
Yes
No
Yes
No
Yes
No
Yes
Quantity*
Up to GPM
48.5
X
18.5
X
47
^ ^
^ ^
Delivery head*
Up to FT
33
X
49
X
38
^ ^
^ ^
Viscosity**
Up to cps
300/500
X
600/800
X
100/300
20,000
20,000
Spec. gravity***
Up to
1.3
X
1.7
X
1.3
*
*
Weight lbs.
Motor + pump tube
24
X
22.2
X
21.6
31.7
31.7
**** SS Rotor with PTFE Stator ^ ^ Consult Burt Process Equipment X Not a suggested combination