To meet the growing challenges of our customers and their environments, Lutz has developed an efficient cost-effective flow meter, using existing measuring technology and state of the art electronics.
The flow meter can be combined with selected accessories to form a complete flow control system.
Type ST
for neutral liquids
such as water, heating oil, diesel and hydraulic fluid
|
Technical data - Type ST
|
Compatibility |
|
consult Lutz
chemical resistance table |
Order No. without relay mdule 0212-101
Order No. with relay mdule
0212-131 Type ST/RM |
Flow volume |
GPM |
min. 2.6 – max. 31.7 |
Temperature |
°F |
140 |
Viscosity |
cps |
2.000 |
Operating pressure |
PSI |
58 |
Accuracy |
|
+/- 1% standard
< 1% with adjustment to application conditions |
Inlet port |
|
2" male thread to fit connector with union nut |
Outlet port |
|
1 1/4" male thread |
LCD display |
|
19 mm (0.75") character height, 6-digit display , individual and total volume reset possible |
Materials
Housing
Measuring chamber
Seals
Magnet |
|
|
PPO |
|
PPO/PPS |
|
FPM |
|
BaFe / PA / stainless steel 1.4401 |
Enclosure |
IP 54 |
IP 54 |
Weight (without RM) |
lbs |
2.2 |
* Depending on use ** Special materials on request General information to the chemical resistance of the different flow meters you will find in our chemical resistance table. |
Type SL
for aggressive acids and caustic solutions
such as hydrocloric acid, sulphuric acid and caustic
|
Technical data - Type SL
|
Compatibility |
|
consult Lutz
chemical resistance table |
Order No. without relay mdule
0212-201
Order No. with relay mdule
0212-231 Type SL/RM |
Flow volume |
GPM |
min. 2.6 – max. 31.7 |
Temperature |
°F |
140 |
Viscosity |
cps |
2.000 |
Operating pressure |
PSI |
58 |
Accuracy |
|
+/- 1% standard
< 1% with adjustment to application conditions |
Inlet port |
|
2" male thread to fit connector with union nut |
Outlet port |
|
1 1/4" male thread |
LCD display |
|
19 mm (0.75") character height, 6-digit display , individual and total volume reset possible |
Materials
Housing
Measuring chamber
Seals
Magnet |
|
|
PPO |
|
PPO/PPS |
|
FPM |
|
PPS encapsulated |
Enclosure |
IP 54 |
IP 54 |
Weight (without RM) |
lbs |
2.2 |
* Depending on use ** Special materials on request General information to the chemical resistance of the different flow meters you will find in our chemical resistance table. |
Type LM
for highly flammable solvents
such as ethanol, petrol, isopropanol, kerosene
|
Technical data - Type LM (Ex)
|
Compatibility |
|
consult Lutz
chemical resistance table |
Order No. |
Flow volume |
GPM |
min. 2.6 – max. 31.7 |
0212-302 |
Temperature |
°F |
140 |
Viscosity |
cps |
2.000 |
Operating pressure |
PSI |
58 |
Accuracy |
|
+/- 1% standard
< 1% with adjustment to application conditions |
Inlet port |
|
2" male thread to fit connector with union nut |
Outlet port |
|
1 1/4" male thread |
LCD display |
|
19 mm (0.75") character height, 6-digit display , individual and total volume reset possible |
Materials Housing Measuring chamber Seals Magnet |
|
|
PPS |
|
LCP |
|
FEP |
|
BaFe / MS / stainless steel 1.4401 |
Enclosure operating unit |
Ex-BE1 |
EEx ib IIA T4 |
Enclosure |
|
IP 54 |
Weight |
lbs |
2.2 |
* Depending on use ** Special materials on request General information to the chemical resistance of the different flow meters you will find in our chemical resistance table. |
Type UN
for highly flammable and aggressive media
such as formic acid, acetic acid, tetrahydrofuran
|
Technical data - Type UN (Ex)
|
Compatibility |
|
consult Lutz
chemical resistance table |
Order No. |
Flow volume |
GPM |
min. 2.6 – max. 31.7 |
0212-402 |
Temperature |
°F |
140 |
Viscosity |
cps |
2.000 |
Operating pressure |
PSI |
58 |
Accuracy |
|
+/- 1% standard
< 1% with adjustment to application conditions |
Inlet port |
|
2" male thread to fit connector with union nut |
Outlet port |
|
1 1/4" male thread |
LCD display |
|
19 mm (0.75") character height, 6-digit display , individual and total volume reset possible |
Materials
Housing
Measuring chamber
Seals
Magnet |
|
|
PPS |
|
LCP |
|
FEP |
|
PPS encapsulated |
Enclosure operating unit |
Ex-BE1 |
EEx ib IIA T4 |
Enclosure |
|
IP 54 |
Weight |
lbs |
2.2 |
* Depending on use ** Special materials on request General information to the chemical resistance of the different flow meters you will find in our chemical resistance table. |
Type VA I
for highly flammable and aggressive media
such as ether, styrene, xylene, nitric acid, tetrahydrofuran
|
Technical data - Type VA I
|
Compatibility |
|
consult Lutz
chemical resistance table |
Order No. without relay mdule
0212-501
Order No. with relay mdule
0212-531 Type VA I/RM |
Flow volume |
GPM |
min. 2.6 – max. 26.4 |
Temperature |
°F |
176 |
Viscosity |
cps |
4.000 |
Operating pressure |
PSI |
145 |
Accuracy |
|
+/- 1% |
Inlet port |
|
1 1/4" male thread |
Outlet port |
|
1 1/4" male thread |
LCD display |
|
19 mm (0.75") character height, 6-digit display , individual and total volume reset possible |
Materials
Housing
Measuring chamber
Seals
Magnet |
|
|
stainless steel (1.4581)** |
|
stainless steel / ETFE / ETFE |
|
FEP |
|
ETFE encapsulated |
Enclosure |
IP 54 |
IP 54 |
Weight (without RM) |
lbs |
7.9 |
* Depending on use ** Special materials on request General information to the chemical resistance of the different flow meters you will find in our chemical resistance table. |
|
Technical data - Type VA I (Ex)
|
Compatibility |
|
consult Lutz
chemical resistance table |
Order No. |
Flow volume |
GPM |
min. 2.6 – max. 26.4 |
0212-502 |
Temperature |
°F |
176 |
Viscosity |
cps |
4.000 |
Operating pressure |
PSI |
145 |
Accuracy |
|
+/- 1% |
Inlet port |
|
1 1/4" male thread |
Outlet port |
|
1 1/4" male thread |
LCD display |
|
19 mm (0.75") character height, 6-digit display , individual and total volume reset possible |
Materials
Housing
Measuring chamber
Seals
Magnet |
|
|
stainless steel (1.4581)** |
|
stainless steel / ETFE / ETFE |
|
FEP |
|
ETFE encapsulated |
Enclosure operating unit |
Ex-BE1 |
EEx ib IIA T4 |
Enclosure |
|
IP 54 |
Weight |
lbs |
7.9 |
* Depending on use ** Special materials on request General information to the chemical resistance of the different flow meters you will find in our chemical resistance table. |
One system for all areas of application
Whether sub totals need to be tracked or continuous tracking is required, whether mobile or stationary, the modular structure guarantees your flexibility and safety.
|